ProFlora pH-Control Touch controller of the JBL trademark is the most exact and modern equipment for constant control and measurement of value rn and temperatures in an aquarium. Advantage of this model is practical, and, above all – the convenient touch control panel of a control system in application. Its big color display with the simple interface and a number of comfortable functions by all means will be pleasant to each aquarian!
Computer reliably, accurately and completely automatically regulates value of level rn in water, and, according to data of the actual and set its value, adjusts giving of CO2 in time. Giving happens thanks to the solenoid valve which in case of excess of carbon dioxide in an aquarium can even stop giving of CO2 completely.
With the CO2/rn level controller – ProFlora pH-Control Touch of a small fish in your aquarium will always be healthy, vigorous and vigorous, and plants magnificent and fine!
Advantage:
- Professional device
- Multilingual and multipurpose menu
- System is capable to compare to convenient touch management most precisely the actual and set values of level rn
- Control system guarantees automatic and timely giving of CO2 in an aquarium for health and comfort of water inhabitants
- and temperatures
- Device has automatic function of a reminder which reminds each 30, 45 or 60 days of calibration
- Existence in a set of all components for fast installation and connection of the controller
Elements and their designation:
1 Assembly level
2 Screws with dowels (on 2 pieces)
3 the Universal power supply with a cable 2 m long and the instrument plug on the secondary party
4 the PROFLORA pH Control Touch Monitor
5 the Color touch
6 screen the Entrance nest for connection of power supply 12 V (direct current) of
7 the Nest for the temperature
8 sensor the Nest of the bayonet BNC socket for the sensor rn
9 an output nest 12 V (direct current) for a connecting cable of the
10 solenoid valve Temperature sensor 10a of the Sucker for the temperature sensor (2 pieces)
11 the Connecting cable for the
12 solenoid valve the Support for calibration glasses
13 the Sensor rn "JBL PROFLORA pH-Sensor +Cal" (a request to get separately!)
separately therefore the client will always receive a fresh electrode. The electrode should be replaced once a year.
Installation (On an illustration the typical example of installation is given):
1 JBL PROFLORA pH Control Touch Instrumentation
2 the Universal
3 power supply Sensor rn
4 the Temperature
5 CO sensor JBL PROFLORA Taifun -reactor
6 the Counter of bubbles "JBL PROFLORA Count safe" with the built-in
7 non-return valve the Connecting cable for the
8 solenoid valve the Solenoid JBL PROFLORA v002 valve
9 the Special hose of giving of CO ₂
Installation of the JBL PROFLORA pH Control Touch instrumentation: At first attach an assembly level by means of both enclosed screws horizontally in the place provided for it on a wall near an aquarium. Now hang up the device with a ledge on a reverse side on the upper edge of a level and slightly press it in front before click. The device can be removed at any time, having shifted it from a level aside.
In a set: CO2-controller with the touch display, including. fastening, the adapter, temperature sensor with 2 suckers and a cable to the solenoid valve, the holder a ditch for calibration liquids
Characteristic:
Display | resistive touch screen 2.8", 16 bits |
Range of measurement of pH | pH 3.00 - 9.00; all values outside range are displayed in the form of 2.99 and (or) 9.01 |
Range of establishment of a preset value rn | 5.00 - 9.00 |
Indication/accuracy of measurement of pH | 0.01 of pH/0.02 pH * |
Range of measurement of temperature | 0.1 - 84 °C |
Accuracy of measurement of temperature | 0.06 °C |
Compensation of temperature | automatic |
calibration Duration | no more than 1.5 minutes on one buffer solution |
Koncentration CO ₂ as a basis of calculation of a curve of auto pH | 22.5 mg/l |
Languages | DE/UK/FR/NL/IT/DK/ES/PT/RO |
Tension | 12 V (direct current) |
Operating tension for the solenoid valve | 12 V (direct current) |
Consumption of power, no more | 0.2 A |
Power supply: | primary tension: 100 - 240 V (alternating current), 47 - 60 Hz, 0.25 Avtorichnoye tension: 12 V (direct current), 0.3 A, 3.6 W |
Material | plasticity the PS/semiconductor |
Colour | white/black |
Package size (for in / x) | 63/295/248 mm |
* depending on age and a condition of the sensor
Producer: JBL, JBL GmbH & Co. KG, Germany
CO2 (carbonic acid)
Characteristics | |
Type of the test | pH (acidity) of CO2 (carbonic acid) |
JBL (GBL) ProFlora pH-Control Touch - The computer for measurement and control of CO2/rn, touch
- Product Code: E-ZOO-101887